Air Cooled Chiller Manufacturers Suppliers

Water cooled chillers pump water through a sealed condenser and disperse it through a cooling tower. Air cooled chillers use fans to force cool air across the condenser. These chillers can be applied to any industrial process that requires year-round cooling, including Hydraulics, plastic molding, chemical, food & pharmaceutical production.

Arrived at KIG in August 2017 was this nice 2005 Temptek Air Cooled Chiller. This is an indoor chiller, and can be used for higher temp manufacturing applications as well. This unit is 208/230 volt SINGLE phase, has a reservoir tank, a 1/2 hp positive displacement pump.

With evaporative cooling condensers, their coefficients-of-performance are very high; typically 4.0 or more. Air cooled condensers are installed and operated outdoors and are cooled with outside air, that is often forced through the condenser using electric fans. Water or liquid cooled condensers are cooled with water that is in turn cooled by a cooling tower. Chilled water is used to cool and dehumidify air in mid- to large-size commercial, industrial, and institutional facilities. Water chillers can be water-cooled, air-cooled, or evaporatively cooled.

Air Comfort can help you select the right type of chiller, and then we can install and maintain it for you. DXS specializes exclusively in the design, installation and service of variable refrigerant flow air conditioning and heating systems. Visit and contact a DXS representative in our Ontario, Texas, and New England offices. In the meantime, the heat absorbed by the refrigerant in the evaporator needs to be transferred to allow the refrigerant to absorb more heat.

chilled water fan coil unit price

As the refrigerant transfers its thermal energy, it begins to condense into a liquid. By the time the refrigerant leaves the condenser, it will be a high pressure, medium temperature, saturated liquid. When the refrigerant enters into the condenser, it will run along the horizontal pipes and transfer its thermal energy into the ambient air stream which is forced by the fans on top. Aqua Series air-cooled chillers feature a compact, all-in-one package design.

There is a BacNet IP card installed and operational All compressors operate properly. 100 PSI low pressure and 132 High pressure with liquid refrigerant present in both circuit liquid lines. The controls indicate that there is 2185 operating hours on each circuit with 2575 starts. Condenser coils appear to be in good condition with no evidence of leaks. Plate and frame evaporator has good insulation with no evidence of leaks. Arrived in January 2018 to KIG were two Carrier Aquasnap 40 ton Air Cooled Chillers.

From solid state to microprocessor based, with communication capabilities to PLC type controls, Mokon can provide the type of control package right for your process. CHPInsight – Powered by CHPInsight Customers may opt to equip their Cogeneration units with our custom CHPInsight software to enhance their equipment’s performance. With our custom dashboard, CHPInsight allows customers to view in real-time their current and historic equipment performance, monetary savings, greenhouse gas reduction, etc. With the majority of our customers selecting long-term maintenance agreements, having the most advanced, reliable equipment monitoring and diagnostic solution protects your valuable equipment for the long-term.

In areas with drought conditions, you may run into restrictions on the use of water-cooled systems as well. Air-cooled chillers don’t use water, so you don’t have to worry about wasting water. They do require a continuous flow of fresh air because they operate by using a condenser that’s cooled by surrounding air.

Chillers provide a continuous flow of coolant to the cold side of a process water system at a desired temperature of about 50°F (10°C). The coolant is then pumped through the process, extracting heat out of one area of a facility (e.g., machinery, process equipment, etc.) as it flows back to the return side of the process water system. Air-cooled chillers are refrigeration systems used in both commercial and industrial facilities to cool fluids and/or dehumidify air.

Of course, this discussion is not confined to the United States. Air-cooled chillers may make sense in many of the areas were people must conserve water. Just like in real estate, decisions for what type of chillers to use are about location, location, location.

The Danfoss Turbocor® TG310 compressor is the first 60-90TR compressor introduced with R1234ze refrigerant, a refrigerant with an extremely low global warming potential. HVAC systems are not only required to meet energy and performance standards but also provide building owners with exceptional benefits. Oil-free systems meet and exceed these standards and demands.

It has switch, piping and plumbing, and solenoid valves to direct flow as needed to a “free cooler” / liquid cooler in winter months if the temperatures support it, so you don’t use your refrigeration energy. That module is not included, and can be obtained from various suppliers like KRACK or similar if you are in a cold environment and interested in that feature. This unit was completely run and tested and checked prior to shipping.

If the system requires less gpm then the pump will reduce in size, meaning less pump energy is used throughout the year. For example, let’s assume the project is a small office building and the owner plans to resell the building within a few years, an air-cooled chiller is often the most desirable in this scenario. However, if the building is a large high school that will be used by the school district for many years, then a water-cooled chiller plant would be the choice to make. In terms of costs, there are fewer components in an air-cooled chiller plant, reducing the initial costs of the plant. Depending on the usage of the building and the building owner type, this cost savings could be a game changer.

Smardt can supply a full package if desired, or on a condenser-less basis. Either way, full warranty applies to all components supplied and commissioned. Condenser coils use a W configuration to optimize heat rejection and footprint. Coils are baked and double-coated as standard with sealed edges as standard, to extend the coil’s physical protection from environmental corrosion towards the inherent long life of the other chiller components. We provide quality products, exceptional service and innovation in all aspects of our operation. Path treatment is a measure taken to increase the resistance of the noise path to prevent the noise from reaching surrounding buildings and the community.